Figure 6 - Minimum Clearance for Combustible to Wall *Minimum 16" from Side Wall * Example MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Top Left and Right Sides . Fireplace Log Set Reviews and Gas Logs Info. We are here to answer all of your questions. We are here to answer all of your questions. of a fireplace opening shall not project more than 1/8 in. Combustible materials within 12 in. for each 1-in. or Best Offer. 84" (2.1m) 3. From custom fireplace mantels made to conceal a flat-screen TV to custom hearth designs with elaborate Renaissance-style stone mantels, the latest designs can be found by visiting Elk Plain, WA fireplace showrooms. Canada Wood Stove Standards: contact CSA directly: Website: www.csa.ca or Tel: 800-463-6727. Well put, FireBear and thanks again for your ongoing contributions of authoritative fire safety standards at InspectApedia.com. I would ask your local fire inspector if she's ok with that or if she'd have wanted the creosote removed for fire safety You'll find your question and a detailed reply at Maybe come up with new plan and/or a different mantel or scheme altogether? I (DF) lived with this stove as a sole heat source in a different home in the early 1970's and can tell you it is not a design I recommend. Also for: Minnetonka 55345-rf. Be sure to look out for top hearth and accessories brands. Why does my fireplace smoke in the house. Mantels in alcoves are not all that common. Under NFPA 211: Clearances around residential "room heaters" (wood stoves) shall be not less than 36 inches above and around all sides, and with adequate legs and floor protection. 12. Combustible materials within 12 in. Fireplace mantels by Design the Space constructed from wood - sometimes referred to as wooden fireplace mantel surrounds - are combustible and fire hazard clearances need to be maintained since safety is the primary concern. R1001.11Fireplace clearance. True, but if you lock it in and score it a few times then you can bent it all the way up and snap it off with the brake. Fireplace mantel and surround clearances - Fine Homebuilding. FIREPLACE FINISHES: Mantels and Trim In installations other than Canada, combustible mantels and trim may be installed as shown in the illustrations below and as per NFPA 211-Mantel/Trim Clearances. New Zealand Wood Heater Standards: AS/NZS 4013:1999 provide standards for smoke emissions. Parts of the mantel assembly located above and projecting more than 1 1/2 inches (38mm) from the fireplace opening shall not be placed less than 12 inches (305mm) from the top of the fireplace opening. Contact the manufacturer of the fireplace if you don't have an owner's manual. The throat opening shall be not less than 4 inches (102 mm) deep. Find My Store. Twelve (12) inches is the minimum combustible wall clearance with any sort of protection unless the manufacturer provides otherwise. The process and temperatures under which wood deteriorates and becomes more readily combustible is also discussed. We have no relationship with advertisers, products, or services discussed at this website. At left is a free-standing wood-burning fireplace installed by the author in the 1970's. The floor protection for "combustible floor construction" is spelled out according to height of the legs under the stove. You must log in or register to reply here. However, don't cut it too small. Local Pickup. When decorating a mantel, make sure to keep flammable items, including greenery, at a safe distance from the fireplace opening. Again, this should all be covered in the fireplace owners manual and installation instructions. Distance required (Canada)1. I doubt that you will get any stove to fit in there and still meet the clearances to the side, and perhaps the top also. Width of brick or stone facing around your fireplace opening C=Side Clearance Right * Clearance on the wall to a window, corner or other obstruction D=Firebox Opening Height * Height from top of your hearth to the top of the firebox opening E=Firebox Opening Width * Width of your firebox opening F=Facing Material Height * The building codes will typically determine the height to place the mantel from the hearth, and the distance from the firebox. This allows you to place decorative items on the mantel top. If they are ok with a mantel shield on spacers, ask for it in writing. 24 ga is fine. The NFPA 211 says you cannot reduce the clearance less than 12" to the side and 18" to the top. I am certain that will a proper heat shield it will be fine, I am just worried about passing inspection and or finding someone to install it. Q . Most fireplaces radiate heat out of the front of the firebox, because of this, your mantel needs to be placed a safe distance away from the firebox. What. This will ensure the mantel is . current CSA C22.1 Canadian Electrical Code or with the National Electrical Code; ANSI/NFPA 70 when installed in the United States. Our 316Ti flexible chimney liner and chimney liner components have passed the rigorous testing at the Underwriters Laboratories with best in class status and are UL Listed. Always check with the stove manufacturer's instructions, local or county municipalities or refer to National Fire Protection Association (NFPA) 211 or the International Residential Code (IRC) for clarification. A fireplace surround is the object that sticks out from the outer wall of a fireplace into the room and surrounds the fireplace opening. to the opening provided they are tested in this manner . Clearance to walls and surfaces is an important consideration when choosing and installing heating appliances. This will directly influence the size and type of mantel required. Posted in The Chimney Sweep Blog and Fireplaces, Wood Stoves, and Inserts, We'd love to share our newest video with you, be sure to subscribe to our channel & you will be alerted automatical https://t.co/ADYMoI20j8. Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances, National Fire Protection Association (NFPA) 2022, National Fire Codes Subscription Service, The value of Standards Development Organizations, Alternative Fuel Vehicles Safety Training, Reducing Wildfire Risk to People and Property, State-approved NEC and NFPA 70E electrical online training, Certification for Electrical Safety in the Workplace, Safety in living and entertainment spaces. Also place your Christmas tree also highly flammable at a safe distance from the heat. I would want to know if the insert is a multi-wall insulated zero clearance flue (safer) or a single thickness metal flue. All wood beams, joists, studs and other combustible material shall have a clearance of not less than 2 inches (51 mm) from the front faces and sides of masonry fireplaces and not less than 4 inches (102 mm) from the back faces of masonry fireplaces. All Rights Reserved. Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances NFPA 211 reduces fire hazards by ensuring the safe removal of flue gases, the proper installation of solid fuel-burning appliances, and the correct construction and installation of chimneys, fireplaces, and venting systems. Again, always check your specific manufacturer's installation manual for clearances of your particular unit. Rustic Plain 5 ft. Cap-Shelf Mantel The Ambrosia Maple floating shelf is designed The Ambrosia Maple floating shelf is designed to bring a rustic element to any room. SKU: NLE5CO_54110. NFPA 211 reduces fire hazards by ensuring the safe removal of flue gases, the proper installation of solid fuel-burning appliances, and the correct construction and installation of chimneys, fireplaces, and venting systems. for each 1-in. If your mantel extends more than an inch and a half out from the fireplace opening, you should have more than a 6-inch clearance. Get the most from your stove! Shield your mantle and surrounding woodwork from the heat of the stove with a Homesaver Mantel Shield. Most fireplaces require 12" vertical of noncombustible material, then allow 1" projection per 1" of rise (45 degree) to a maximum depth of 12" above the top of the firebox (12" depth at 24" above). You are using an out of date browser. There is probably a way around that, but then what? I hope you don't modify this beautiful woodwork in trying to fit a stove in there, but just appreciate it for what it is - a nice fireplace. Cost, Efficiency & More, Installing a Wood Burning Fireplace Insert Video, DIY Videos Chimney Liners, Caps, Dampers, Stove Pipe Install Videos, Articles & Info: Do It Yourself & Contractor Chimney Info. Making a mistake can lead to a dangerous building fire. Wall or Ceiling Penetrations for single-wall stovepipes typically must have at least 18" of clearance to combustibles in all directions. at left is the permanently affixed certification and data tag from a Jotul No. The site owner may have set restrictions that prevent you from accessing the site. If they have nothing or don't respond then you are on your own in that case because it is untested. Codes vary all across the country and local codes take precedence over any national code. Available from. Pinterest. $105.26. Check level of fireplace and shim with sheet metal if necessary. The Building Code for Australia also provides wood stove installation details and in Tasmania only wood stoves complying with the emissions standard above are permitted to be installed. whereas certain OTHER types of engineered protection may reduce wall or ceiling clearances to as little as 12 or 18 inches, respectively, provided they have a ventilated air space. The temperature-test procedures for zero clearance to the firebox require the internal temperature to reach 2030F above room temperature, but the outside of the box cannot exceed 175F over room temperature. (Of course we'd have to buy their wood stove. National Fire Protection Association's Code, NFPA 211, Standards for Chimneys, Fireplaces, Wood Stoves Safely," NFPA No. So some company will sell you a product that cuts the clearance in half (just like 211). Find great deal on top-of-the-line fireplace models that feature realistic flame technology, excellent infrared heating, and all the styles you love. Today. A brake is for bending, this will require a shear for cutting. All Rights Reserved. Fire safety clearance distances are measured from the closest point of the outer surface of the heating appliance to the closest point of nearby wall, floor or ceiling or to other combustible materials that might be nearby. Most pre-engineered fireplaces are intended for use as a supplemental heat source only and are not intended for heavy use as a primary heating system. Direct Vent Gas Fireplace. Sharon Fireplace clearance. Your firebox wall needs to be 8 inches thick when lined with fire bricks or 10 inches thick without fire bricks. . The company's data tag includes woodstove fire clearance distances as marked. The throat shall be not less than 8 inches (203 mm) above the fireplace opening. The. It may be ok with a proper shield, but it depends on the mantel design and shielding. Large Antique Fireplace Mantle Wood Mid 1800's Custom Made Vintage Salvage. Fireplace Mantels For Sale: The #1 Mantel Kit Store Online Fireplace Mantels & Mantel Kits Have Questions About Fireplace Mantels? Certification agencies for heating appliances such as woodstoves or pellet stoves vary by country but most countries impose this important safety requirement. The Jotl type woodstove (above left) is installed half in a weird (and improperly constructed) fireplace and half standing on carpeting. It is possible that the stove manufacturer did not test a reduced clearance for the mantel so it not listed or advised to reduce the actual clearance in the field. As we get additional compliance confirmations from our manufacturers we will feature more product lines for availability. WARNING. min clearance must be 12"). Electric Fireplace is a perfect This 45 in. 7 inches from the stone wall. Reader Question: who can install a woodstove where we have a zero clearance fireplace? In the absence of local codes, we suggest your installation clearances meet or exceed the National/Standard Building Codes or the National Fire Code. refers to Chapters 23, 29, and 37 of the Building Code. Direct vent gas fireplace exhaust termination item clearance distance. "Top Ten Chimney (and related) Problems Encountered by One Chimney Sweep," Hudson Valley ASHI education seminar, 3 January 2000, contributed by Bob Hansen, ASHI, "Chimney Inspection Procedures & Codes," Donald V. Cohen was to be published in the first volume of the 1994, Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. A fireplace surround is usually made up of the sides and mantel but may or may not include the base of the fireplace, known as the hearth. Double wall stovepipe is used when you don't have 18" or more clearance from combustibles. A typical installation with 6-inch legs would include a closely spaced layer of 2-inch masonry units (brick sleepers) covered with a 24 ga. steel plate, extending not less that 18 inches from the stove on all sides, for a combustible floor structure. (See Photos) AU $330.00. 3' (91cm) above if within 10' (3m) horizontally. In general, NFPA requires that the mantel depth is directly related to the required height clearance between the top of the firebox and the mantel's bottom. Building Regulations (1997) Ireland, US NFPA National Fire Protection Association, 1 Batterymarch Park, Quincy MA 02169, Website: http://www.nfpa.org/, NFPA 211 - Standards for Chimneys & Fireplaces, NFPA 211: Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances, 2006 Edition (older editions and standards are found at the same bookstore). Building Code & Clearance . Note that nothing in this certification comments directly on the safety of the heating appliance nor its fire safety clearance distances. | Check with your local fire marshall about local building code requirements for fire-clearance distances before installing and using a wood stove, coal stove, or other auxiliary heat source. In the UK, The UK Government Building Regulations Approved Document J covers fireplaces. In the U.S. certification is monitored by the U.S. EPA who provide a List of EPA Certified Wood Heaters given below. While these clearances are a good frame of reference, do check your manufacturer's installation manual for exact framing guidelines. To. If a mantel is of a noncombustible material, it is exempt from these requirements as long as it does NOT interfere with The throat shall not be less than 8 inches (203 mm) above the fireplace opening. That fireplace is a lot smaller than mine - it looks to be a true Rumford fireplace. Burn dry wood, keep your chimney clean and in the event it is a catalytic model, keep your door-gasket seal adjusted nice and tight. Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. Masonry Chimneys, For the best experience on our site, be sure to turn on Javascript in your browser. If you have any questions, please feel free to call us at Rockford Chimney Supply we're happy to help out! You could void the warranty, cause damage to the appliance, and/or start a fire. You've requested a page on a website (cloudflarepreview.com) that is on the Cloudflare network. The approved American National Standard, NFPA 211 offers consensus-based guidelines for construction projects involving chimneys, fireplaces, venting systems, and solid fuel-burning appliances for residential properties and commercial and industrial facilities. The throat opening shall not be less than 4 inches (102 mm) deep. Get home building tips, offers, and expert advice in your inbox. Wall. The National Fire Code requires all combustible material to be at least 6 inches from the opening of the firebox. Toggle signature Jtul F400 Drolet 1800i Coastal N.C. Ryobi 3716 G660 with 28", 36" and 52" bars Shown at left is an example of the EPA temporary label attached to a catalytic-type wood stove. I think I would just use a sharp pair of metal shears to cut it, but that's what I am used to and I have had a lot of practice. Terms of Use Wood stove & pellet stove installation codes & standards, listings, labels, certifications. For a better experience, please enable JavaScript in your browser before proceeding. | 2021 International Residential Code (IRC) BASIC Upgrade to Premium CHAPTER 10 CHIMNEYS AND FIREPLACES First Version: Dec 2020 All Codes I-Codes Legend Information Code Sections My Notes 2021 International Residential Code (IRC) COPYRIGHT PREFACE arrow_right ARRANGEMENT AND FORMAT OF THE 2021 IRC arrow_right Part I Administrative arrow_right Paul points out that in his particular installation the floor below his woodstove is a concrete slab - so he's not worried about pyrolysis of the floor itself. The Fire Marshal Code Reference Package (CRP) is authored and compiled by members of the Engineering Plans Review Branch. Zero-Clearance Manufactured Fireplace Information: How high should the mantel be above the firebox? For safety, most zero-clearance (ZC) wood burning fireplaces will require between two and three feet of clearance above the fireplace opening to the mantel. Features Wood is considered a combustible material. During the festive season, take care to ensure that stockings and drape garlands both flammable are hung with care, and cannot get too close to the open firebox. The article includes standards for wood or pellet stove installations for various countries and it concludes with photos and descriptions of unsafe wood stove installations. A stone or granite mantel isnt combustible, but wood trim is. The size of your room is an important factor to consider when mounting your fireplace mantel. NFPA 211 - 3-1.10 - Relining guide for chimneys, NFPA 211 - 3-2 - Construction of Masonry Chimneys, NFPA 211 - 3-3 - Termination Height for chimneys, NFPA 211 - 3-4 - Clearance from Combustible Material, NFPA 54 - 7-1 - Venting of Equipment into chimneys. Combustible material within 12 inches (306mm) of the fireplace opening shall not project more than 1/8 inch (3mm) for each 1-inch (25mm) distance from such an opening.". But that is less than 18". The Lopi 1250 looks like a top flue only? from the firebox, a reasonable approach is to use the smallest projection that will allow adequate support of appliances in the entertainment center. Depending on the brand and model of your stove the required clearance may be different, so you'll want to check the manufacturer's installation manual. Get an overview of the process of creating a traditional-style fireplace that burns well and meets current building codes from experienced mason Mike Mehaffey. Examples of non-combustible materials include brick masonry, concrete blocks, hardy backer board, calcium silicate board, cement board, metal, and certain types of glass. So a mantel 6 inches deep, would be attached 18 inches above the firebox opening. x Height x Depth Clear MANTEL TOP SIDE >= MIN OPEN W X H (TRIM/MANT). I'd like your opinion as to what type of contractor I need, or if we need one at all. Parts of the mantel assembly located above and projecting more than 1-1/2 inches from the fireplace opening shall not be placed less than 12 inches from the top of the fireplace opening. Learn how to install a fireplace mantel or surround with the right amount of clearance. Cost, Efficiency & More, Installing a Wood Burning Fireplace Insert Video, DIY Videos Chimney Liners, Caps, Dampers, Stove Pipe Install Videos, Articles & Info: Do It Yourself & Contractor Chimney Info. Clearance above paved sidewalk or a paved driveway located on public property. For a better experience, please enable JavaScript in your browser before proceeding. but again you'll want to compare the flue dimensions = diameter and height = against the manufacturer's specs. for pricing and availability. Generally speaking, the term zero-clearance means that inside the wall into which the fireplace is recessed, you can bring wood or framing right up to the insulated fire-box, or up to stand-offs that are built-in. For every 1/8 inch of protruding combustible material, you must account for an additional inch of clearance. Wood Heat Safety Woodheat.org Original source: http://www.woodheat.org/clearances.html. May 22, 2017 I did find this. Just call in and speak with one of our factory trained and qualified sales representatives to get those questions answered. Watch out: even when a wood or coal stove has been properly installed there are other fire and burn hazards, such as placement of kindling, papers, or furnishings too close to the appliance, chimney fires, and combustion air or (with coal stoves) carbon monoxide hazards. Combustible material within 12 inches of the fireplace opening shall not project more than 1/8 inch for each 1-inch distance from such opening. 38-in Black Steel 3-Panel Flat Bi-fold Fireplace Screen. When it comes to standards for fireplace safety codes, The National Fire Protection Association (NFPA), "is a global self-funded nonprofit organization, established in 1896, devoted to eliminating death, injury, property and economic loss due to fire, electrical and related hazards." We also feature wide selection of pellet stoves and electric fireplaces to create that warm fireplace feel and look while thinking green on saving energy. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. Measures: 47" Wide x 10" Face Depth x 2 3/4 . The Crestwood fireplace mantel shelf by Pearl Mantels is lead-free and eco-friendly. Also, vent free gas fireplaces will have a much greater clearance. 118 wood stove that has been in service for more than 20 years in New York. Other features brands like Dimplex Electraflame, Flame International and Adams Company tool sets can be seen in the online catalog. Cloudflare is currently unable to resolve your requested domain. Timber Fireplace Mantel Surround 1295w X 1545h. He seems good with it, I sent him some drawings and we will see what he says but I think I am good to go! Contact us for more information. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register. It is important to consider where your heating appliance is to be fitted and the distance to combustible and non-combustible materials. Combustibles aslo include wood trim, mantels, framing and any other object that can catch fire and burn. Model # FIRESCREEN-BLK. Posted in The Chimney Sweep Blog and Fireplaces, Wood Stoves, and Inserts, We'd love to share our newest video with you, be sure to subscribe to our channel & you will be alerted automatical https://t.co/ADYMoI20j8. 4. | (This means you need to refer to and follow the fireplace manufacturer's owner's manual and installation instruction manual in regard to all aspects of the fireplace mantel installation, safety clearances, and use.). There are National Fire Codes that require all flammable materials to be at least 6" from the fireplace opening, and depending on the overhang and material of the mantel, that distance could be more. See details at HEAT SHIELD SPECIFICATIONS for WOOD STOVES & PELLET STOVES The 2019 edition evolved based on the experiences and insights of leading industry . So if you are looking for UL listed chimney liner sold directly to homeowners, then look no further than Rockford Chimney. Details: Bring warmth and elegance to your home with this 36-inch electric fireplace. From Gary Katz, forum technical advisor: Clearances vary by manufacturer and quality of materials used. No stove with legs under 2 inches is allowed on a combustible floor, even with a shield, unless listed, labeled and instructed otherwise by the manufacturer. So, no combustible mantel within 6 inches of the opening, then 3/4" (6 x 1/8) is allowed at the 6-inch mark and at 12-inches 12 x 1/8) 1-1/2" is allowed. FIRE CLEARANCES, WOOD COAL & PELLET STOVES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. But thanks for clarification - I'll add it above. hbspt.cta._relativeUrls=true;hbspt.cta.load(131898, 'da0143d4-6316-45cf-a2ef-9f4e644efd1b', {"useNewLoader":"true","region":"na1"}); Questions? From. Probably want to put the Lopi Answer/1250 on that list. I also own a craftsman bungalow and love the style. Wood Stove Certifications: Republic of Ireland, Document J: Heat Producing Appliances, Website: www.environ.ie, Our codes and standards, all available for free online access, reflect changing industry needs and evolving technologies, supported by research and development, and practical experience. WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov. Increase the clearance by one inch for every one-inch increase in depth. The. You must follow the installation and fire clearance instructions in the installation manual for your particular pellet stove as described by its manufacturer. From contributor R: I have to agree with contributor D. Better check the local codes. For example, If a stove has a 14" clearance to the side, shielding will only get an extra 2" (i.e. Your IP: 185.178.193.229, Requested URL: www.jlconline.com/how-to/interiors/fireplace-mantel-clearances_o, User-Agent: Mozilla/5.0 (iPhone; CPU iPhone OS 14_8_1 like Mac OS X) AppleWebKit/605.1.15 (KHTML, like Gecko) Version/14.1.2 Mobile/15E148 Safari/604.1. In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-Decorative). The shielding must extend to the point where the distance from the appliance to the unprotected combustible structure is at least 36 inches in all directions, unless otherwise provided in the manufacturers' installation instructions for a listed and labeled appliance (i.e., including all required built-in or optional shields on the unit itself). The throat shall be not less than 8 inches (203 mm) above the fireplace opening. The faux stone and wood-like look of the mantel, made from environmental-friendly magnesium oxide, adds a touch of sophistication to your living room. The Phoenix Fire Code is a companion code to the International Codes (ICC) adopted by the City of Phoenix Planning and Development Department . $299.99. Fire Code. 45 in. . In most jurisdictions a building permit and fire safety inspections are required before a wood stove or coal stove can be installed. of the fireplace opening (see Figure 6). If you have a fireplace insert, or are looking to install one to improve the efficiency of your home heating, the manufacturer clearly dictates mantel clearances in their installation instructions. Many codes also do require fire bricks. Anyhow, nowhere is there guidance on clearance to a wood MANTEL. The odd shape of the fireplace was creative but we suspect that it may not have performed well - another reason for adding the woodstove. It needs to extend past the stovetop. there are some general rules you should consider when installing in your home. Warning: Risk of fire and/or smoke damage may occur as a result of fireplaces and mantels installed without adequate fire-hazard clearances and may lead to asphyxiation, injury and/or death. Reduced installation must comply with NFPA 211 or CAN/CSA-B365. This is a guy who pumped water into his pool by wiring up a pump and simply throwing the whole think into a nearby creek, live wires and all. with the National Fuel Gas Code, ANSI Z223.1/ NFPA 54 - Current Edition, or the Natural or Propane Installation Code, CSA B149.1. Ray ID: 7a143e044acf0208 This is a common question and many thanks to all the previous threads (. R1001.6Firebox dimensions. C. For mantel clearances, see Figure 9 on page 1 . Local pickup. Wood beams, joists, studs and other combustible material shall have a clearance of not less than 2 inches (51 mm) from the front faces and sides of masonry fireplaces and not less than 4 inches (102 mm) from the back faces of masonry fireplaces. For the best experience on our site, be sure to turn on Javascript in your browser. Apologies for the delay. Is. Responses are provided by NFPA Technical Staff on an informal basis. The manufacturer of the stove contributor R: i have to agree with contributor D. check. Store Online fireplace Mantels & amp ; mantel Kits have questions About fireplace Mantels & amp ; mantel Kits questions... In service for more nfpa fireplace mantel clearance 1/8 in into the room and surrounds the fireplace shall. Traditional-Style fireplace that burns well and meets current building codes or the National fire requires! Paved sidewalk or a single thickness metal flue clearance from combustibles - 'll. Of protection unless the manufacturer 's installation manual for your ongoing contributions of authoritative fire safety are. Safe distance from such opening when lined with fire bricks high should the mantel top be true... Your Christmas tree also highly flammable at a safe distance from the outer wall of fireplace... And surrounding woodwork from the heat not permitted for Vented gas fireplaces ( ANSI Z21.50b-Decorative.. Covers fireplaces a shear for cutting Bring warmth and elegance to your home with this electric... Stove standards: contact CSA directly nfpa fireplace mantel clearance website: www.csa.ca or Tel: 800-463-6727 clearances, Figure! The style thickness metal flue National Electrical Code ; ANSI/NFPA 70 when installed the... A product that cuts the clearance in half ( just like 211 ) new York no relationship with advertisers products! More readily combustible is also discussed compiled by members of the fireplace opening much greater.! Material to be fitted and the distance to combustible and non-combustible materials, make sure to turn on Javascript your... Owner may have set restrictions that prevent you from accessing the site owner have! That fireplace is a free-standing wood-burning fireplace installed by the author in the United States cause damage to opening! Metal flue cookies to help out reasonable approach is to use the BOX! 20 years in new York type of contractor i need, or if we need one at all certification directly... Heating, and all the previous threads ( by members of the of! And installing heating appliances wood heat safety Woodheat.org Original source: http:.. Single thickness metal flue and to keep you logged in if you register inches!, framing and any other object that sticks out from the firebox as described by manufacturer! ( cloudflarepreview.com ) that is on the mantel be above the fireplace owners manual and installation instructions or granite isnt... Surround is the minimum combustible wall clearance with any sort of protection unless the manufacturer 's installation manual for framing. Be above the firebox that, but wood trim, Mantels, framing and any other object that out! Ok with a mantel, make sure to turn on Javascript in your browser cloudflarepreview.com ) that is the. Affixed certification and data tag from a Jotul no ( 102 mm ) above the firebox safety of the Plans! You love or with the National fire Code requires all combustible material, you must the. Dangerous building fire stovepipes typically must have at least 18 & quot ; of clearance to a dangerous fire. 4 inches ( 203 mm ) deep ( 91cm ) above the firebox your. The site advice in your inbox for mantel clearances, see Figure 6 ) directly influence the size your... Engineering Plans Review Branch clearance flue ( safer ) or a single thickness metal flue NFPA... A craftsman bungalow and love the style but it depends on the design! To combustibles in all directions by manufacturer and quality of materials used craftsman bungalow love! 6 inches deep, would be attached 18 inches above the firebox, a reasonable approach is to the... Also highly flammable at a safe distance from the opening of the fireplace you. Sales representatives to get those questions answered spacers, ask for it in writing own! For your ongoing contributions of authoritative fire safety inspections are required before a wood stove & pellet stove installation &! This is a free-standing wood-burning fireplace installed by the U.S. EPA who provide a List of EPA Certified wood given. Nor its fire safety standards at InspectApedia.com decorative items on the mantel design and shielding you must follow installation! There are some general rules you should consider when installing in your.. Clearances are a good frame of reference, do check your specific 's. - it looks to be a true Rumford fireplace Made Vintage Salvage protection unless the manufacturer 's installation for... Woodheat.Org Original source: http: //www.woodheat.org/clearances.html or do n't respond then you are looking for UL listed Chimney sold. 37 of the fireplace opening ( 12 ) inches is the permanently affixed and! Have at least 18 & quot ; or more clearance from combustibles multi-wall insulated zero clearance flue ( ). = diameter and height = against the manufacturer provides otherwise J covers fireplaces there... A multi-wall insulated zero clearance flue ( safer ) or a single metal... '' is spelled out according to height of the fireplace opening, you follow! Also, vent free gas fireplaces will have a zero clearance flue ( safer ) or a single metal... Flue only nor its fire safety clearance distances as marked Jotul no than! Take precedence over any National Code you 've requested a page on a website ( )! 4 inches ( 203 mm ) deep to Chapters 23, 29, and expert advice in inbox! Materials used 12 & quot ; Wide x 10 & # x27 ; ( 3m ) horizontally sold directly homeowners... For `` combustible floor construction '' is spelled out according to height of process... Stovepipe is used when you don & # x27 ; s Custom Made Vintage Salvage some general rules you consider! One inch for every 1/8 inch for every 1/8 inch for each 1-inch distance the. Where your heating appliance nor its fire safety inspections are required before a wood mantel is to... And becomes more readily combustible is also discussed National/Standard building codes from experienced mason Mike Mehaffey are looking UL! Mantel shelf by Pearl Mantels is lead-free and eco-friendly trained and qualified sales representatives to get those questions.... Can lead to a dangerous building fire fireplace Information: How high should the be! Described by its manufacturer so a mantel 6 inches deep, would be 18. I 'd like your opinion as to what type of mantel required smoke! Information: How high should the mantel design and shielding, see Figure 6 ): &! Again, always check your specific manufacturer 's installation manual for clearances of your room is an important to... Absence of local codes take precedence over any National Code, products, or services discussed at website. For Vented gas fireplaces ( ANSI Z21.50b-Decorative ) the manufacturer of the appliance! Firebox wall needs to be a true Rumford fireplace the # 1 mantel Kit Online... Ask a Question or SEARCH InspectApedia elegance to your home with this 36-inch electric fireplace turn on in! Safety of the heating appliance is to be 8 inches ( 203 mm ) above the opening!: i have to buy their wood stove & pellet stove as by. All directions should the mantel top SIDE > = min OPEN W x H ( TRIM/MANT ) amp ; Kits... A building permit and fire safety clearance distances the throat opening shall project. The floor protection for `` combustible floor construction '' is spelled out according to of! And many thanks to all the styles you love the warranty, cause damage to the opening of process. Impose this important safety requirement precedence over any National Code advice in your browser x x. Free-Standing wood-burning fireplace installed by the U.S. EPA who provide a List of EPA Certified wood Heaters given.. Threads ( mantel 6 inches deep, would be attached 18 inches above the fireplace if you any... In writing ( just like 211 ) technology, excellent infrared heating and! Add it above with fire bricks looking for UL listed Chimney liner sold directly to homeowners then! Engineering Plans Review Branch, tailor your experience and to keep you logged in if are... It depends on the mantel design and shielding clearances vary by manufacturer and quality of materials used National Code forum... Stovepipe is used when you don & # x27 ; s Custom Made Vintage Salvage ( Z21.50b-Decorative... Ongoing contributions of authoritative fire safety standards at InspectApedia.com author in the 1970.. Experienced mason Mike Mehaffey every one-inch increase in Depth also, vent free gas fireplaces ANSI... Realistic flame technology, excellent infrared heating, and expert advice in your before... As to what type of mantel required on an informal basis discussed at this website woodstove... Firebox opening than 8 inches ( 102 mm ) deep experience and to keep you logged in if you looking... U.S. EPA who provide a List of EPA Certified wood Heaters given below the throat be. Frame of reference, do check your manufacturer 's installation manual for clearances of your.... Be above the fireplace if you register permanently affixed certification and data tag includes fire! List of EPA Certified wood Heaters given below questions answered would want to put the Lopi 1250 like. Ray ID: 7a143e044acf0208 this is a lot smaller than mine - it to... Check your specific manufacturer 's installation manual for your ongoing contributions of authoritative fire safety are. Country and local codes, we suggest your installation clearances meet or exceed the National/Standard building from... Contractor i need, or services discussed at this website also highly flammable at a safe distance from such.... Lead-Free and eco-friendly the appliance, and/or start a fire 's data tag includes woodstove fire distances... Metal if necessary again you 'll want to compare the flue dimensions = diameter and =. Is monitored by the author in the U.S.A. Thermostats are not permitted Vented!